Data Cable - Type 50191

Construction characteristics

Conductor: 0.50 mm² stranded bare copper conductor, IEC 60228 class 6 or equivalent, insulated with Polyolefin. Nominal OD 1.8 mm, black with white numbers 1-19 (19 each)

Filler: Fillers where needed for roundness

Tape: Binder tapes

Screen: Tinned copper braid – coverage ≥ 85%

Tape: Waterblocking tape

Outer jacket: Polyurethane, colour: Blue – glossy finish. Nomincal thickness 1.15 mm. Marking on cable: Data cable type 50191 /08mmyy

European directives: 2002/95/CE (RoHS – Reduction of Hazardous Substances) and 2002/96/CE (WEEE – Waste from Electronic Equipment)

 

Mechanical characteristics

Outer diameter: 13.0 mm ±0.40 mm

Weight in air: 289 kg/km

Weight in seawater: 157 kg/km

Min. bending radius, static: 130 mm

Min. bending radius, dynamic: 195 mm

Depth rating: 6,000 m

Operating temperature range: -40°C - +80°C


Electrical characteristics

Working voltage: 250 V

Test voltage: 1,000 V VAC x 1 min.