Power/Ethernet cable - Type 4480/K

Local sales contact

Loading…








Construction characteristics

Ethernet element: (cat. 6) 2 x 0.13 mm² (26 AWG), 19 tinned copper conductor
insulated with special polymer. 2 cores twisted together and
wrapped with plastic foil or non woven tape (4 each). Colour:
White/orange, white/green, white/blue, white/brown. 4 pairs twisted together with
overall aluminium plastic foil and tinned copper braid. Coverage ≥ 85% (1 each)
Conductor: 1 mm² (18 AWG) bare copper conductor insulated with special polymer
Nominal diameter 2.70 mm (4 each). Black, numbered 1-4
Filler: Water blocked compound
Shield: Tinned copper braid. Coverage ≥ 85%
Inner jacket: Polyurethane. Colour blue
Strength member: Para-aramidic fibre braid
Outer jacket: Polyurethane. Colour blue

 

Mechanical characteristics

Diameter: 16.10 mm ±0.5 mm
Weight in air: 330 kg/km
Weight in seawater: 120 kg/km
Min. bending radius: 161 mm
Strength member: breaking load 20 kN
Depth rating: TBA
Operating temperature range: -20°C - +80°C

 

Electrical characteristics

Operating voltage: 1,000 V for 1 mm² conductor
Test voltage: 4,000 Vac x 10 min for 1 mm² conductor
1,000 Veff x 1 min for 4 x 2 AWG26 (cat. 6)
Conductor resistance: 19.5 Ω/km max for 1 mm² conductor
145 Ω/km max for 4 x 2 AWG26 (cat. 6)
Insulation resistance: ≥ 5 GΩxkm for 1 mm² conductor + 4 x 2 AWG26 (cat. 6)

 

4 x 2 x 26 AWG (cat. 6)

Capacitance: 55 pF/m (cond./cond.) at 800 Hz
110 pF/m (cond./shield) at 800 Hz
Attenuation: ≤ 2.8 dB/100 m at 1.0 MHz
≤ 9.0 dB/100 m at 10.0 MHz
≤ 30.2 dB/100 m at 100 MHz
Impedance nom.: 122 Zu (Ω) / 82 Zo (Ω) at 1.0 MHz
112 Zu (Ω) / 89 Zo (Ω) at 10.0 MHz
125 Zu (Ω) / 80 Zo (Ω) at 100 MHz